Solutions Recovery International (SRI) is a full-service engineering company capable of providing Mechanical, Electrical, Chemical, Civil, structural engineering and Fire Safety and code compliance services. Depending upon the scope of project SRI can also provide turnkey services for Semiconductor, Plating, PCB, Dairy and Winery industries. SRI is committed to client satisfaction by providing the most innovative engineering solutions and customer service.

Play Video

We are Engineers, Scientists and Contractors

SRI also offers a full line of proven Treatment/Recycling/Reuse technologies that can recycle up to 95% of the  rinse water from your operation. These technologies have resulted in tremendous saving in water and treatment chemicals. In some cases the product water is deionized water, which can also improve products’ quality.

Waste Water Neutralization Calculations_U S

1. Caustic Addition – (pH is too low and must be raised)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs
Calculations

gmp

WW Flow Rate, Qww =

gal/day

Moles/L of OH needed =

moles/L

Incoming pH, pHin =

NaOH rate needed =

moles/day

Desired pH, pHout =

Caustic solution rate =

lb/day

Caustic sol’n % NaOH =

Caustic solution rate =

gal/day

Caustic sol’n density, ρ =

lb/gal

Daily cost of caustic =

$/day

Caustic solution cost =

$/lb

Wastewater Neutralization Calculations – U.S. units
1. Caustic Addition – (pH is too low and must be raised)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs

gmp

WW Flow Rate, Qww =

gal/day

Incoming pH, pHin =

Desired pH, pHout =

Caustic sol’n % NaOH =

Caustic sol’n density, ρ =

lb/gal

Caustic solution cost =

$/lb

Calculations

Moles/L of OH needed =

moles/L

NaOH rate needed =

moles/day

Caustic solution rate =

lb/day

Caustic solution rate =

gal/day

Daily cost of caustic =

$/day

Wastewater Neutralization Calculations – U.S. units
2. Acid Addition – (pH is too high and must be lowered)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs
Calculations

gmp

WW Flow Rate, Qww =

gal/day

Moles/L of H+ needed =

moles/L

Incoming pH, pHin =

H2SO4 rate needed =

moles/day

Desired pH, pHout =

Acid solution rate =

lb/day

Acid sol’n % H2SO4 =

Acid solution rate =

gal/day

Acid sol’n density, ρ =

lb/gal

Daily cost of acid =

$/day

Acid solution cost =

$/lb

Wastewater Neutralization Calculations – U.S. units
2. Acid Addition – (pH is too high and must be lowered)
Instructions: Enter values in blue boxes. Spreadsheet calculates values in yellow boxes
Inputs

gmp

WW Flow Rate, Qww =

gal/day

Incoming pH, pHin =

Desired pH, pHout =

Acid sol’n % H2SO4 =

Acid sol’n density, ρ =

lb/gal

Acid solution cost =

$/lb

Calculations

Moles/L of H+ needed =

moles/L

H2SO4 rate needed =

moles/day

Acid solution rate =

lb/day

Acid solution rate =

gal/day

Daily cost of acid =

$/day